A giraffe’s brain needs a continuous supply of blood whether its head is high above the heart or lowered towards the ground. Gravity changes that task: raising the head means sending blood upwards, while lowering it changes the pressure along the route. The vessels themselves are therefore part of the question, alongside the pumping heart.
Marna S. van der Walt and colleagues investigated a mesh of small arteries beneath the brain in a 2023 Anatomia paper. Dissection located the network, and microscope sections showed muscle in its vessel walls. To explore a possible effect of its winding routes, the researchers also sent water through coiled plastic tubes. Longer tubes carried less water per minute. Connecting these observations to regulation in a living giraffe is the next step in the argument, rather than something the apparatus measured directly.
Following the blood vessels beneath the brain
The team obtained material from five giraffes culled during reserve management in South Africa. The researchers were not involved in organizing those culls. Different specimens contributed to dissection, tissue microscopy and casts of the cavity holding the brain.
For four heads, the team introduced colored latex into the blood vessels: red for arteries and blue for veins. Once set, the latex helped them follow the vascular pathways through the neck and skull. The main arterial supply leads towards a compact network immediately beneath the brain, inside a space called the cavernous venous sinus. The network’s anatomical name is the rostral epidural rete mirabile; here, “rete” means the mesh of interconnected vessels.
The dissection revealed a conspicuous bend as the maxillary artery approached the rete, followed by much finer vessels in the network itself. The arrangement gives researchers something concrete to investigate: blood moving along a supply artery then divides among narrower, interconnected routes.
The latex did not fully enter those fine vessels. As a result, the authors could not reconstruct and measure the complete network. In particular, its total vessel length remained unknown—a crucial point when interpreting the separate tubing experiment.
Vessel walls that could change the flow
Microscopic sections from one head showed the walls of arteries before, within and after the rete. Stains distinguished muscle, collagen and elastic fibers. The muscular middle layer was thinner in the small rete arteries than in the larger vessels sampled on either side, but the rete arteries still contained substantial smooth muscle.
That matters because smooth muscle can change an artery’s diameter. A narrower passage offers greater resistance to flow; a wider one changes that resistance. The authors proposed that contraction of the network could also help direct a small volume of blood towards the brain when the head rises.
The tissue establishes the presence of muscle, not the timing or amount of any contraction. The researchers did not observe these vessels changing diameter during head movement. Their anatomy supplies a plausible mechanism to test.
What happened in the coiled tube
The physical experiment isolated a simpler question: how would flow change through winding tubes of different lengths? The researchers used plastic tubing with a four-millimetre diameter, wound around a pipe. Lengths ranged from half a metre to six metres. They passed room-temperature water through each setup, measured the amount flowing in one minute, and repeated each length’s test five times.
Water flow was about 648 millilitres per minute through the shortest tube and 275 through the longest. In that apparatus, the longer route carried less water each minute. The result demonstrates a physical effect that could be relevant when thinking about a route’s resistance to flow.
The experiment changed length as well as the number of turns, however. It cannot identify how much of the effect came from bends alone. Nor are those test lengths measurements of the giraffe rete: incomplete latex filling prevented the team from obtaining its actual length.
The difference between one tube and many branches is equally important. In the animal, blood can divide among interconnected vessels; in the apparatus, water followed one continuous tube. The authors acknowledged this limitation of their serial arrangement. Plastic also cannot reproduce a living wall’s ability to change diameter. The reported water-flow values consequently belong to the apparatus, rather than to a giraffe’s brain circulation.
The next link is the network in action
Van der Walt and colleagues proposed that the rete contributes both to managing flow towards the lowered head and to maintaining supply as it rises. Their combination of dissection, microscopy and a physical experiment gives those ideas an anatomical and mechanical basis for further investigation.
Establishing the network’s contribution during head movement would require measurements or models closer to the real branching geometry and operating conditions. This study did not directly record pressure and flow on either side of the rete in a living giraffe, so it cannot quantify its buffering effect or assign this structure the whole explanation for avoiding fainting.
For the wider problem of delivering blood up a long neck, our giraffe heart and blood-pressure guide explains the pumping challenge. The drinking and blood-flow story follows a different approach to the effects of head position. Read alongside those questions, this paper’s particular contribution is clear: the arterial mesh is real, its muscle is visible, and a simplified winding route changes flow. How those features work together inside a moving giraffe remains to be measured.
Sources
Marna S. van der Walt, Willem Daffue, Jacqueline Goedhals, Sean van der Merwe and Francois Deacon (2023). “The Rostral Epidural Rete Mirabile: Functional Significance in Blood Flow Regulatory Mechanisms in Giraffe (Giraffa camelopardalis).” Anatomia 2, 138–155. Full paper.




